RailwayData | Bridges - HSA 17 - Stratford/avon Canal

STRATFORD/AVON CANAL

Structure Overview

Asset Name: Stratford/avon Canal
Asset Type: Bridge (Underline Bridge)
Operational Status: Functionary

Location Details

ELR & Structure Ref: HSA 17
Railway Location: 9m 13ch / 9m 0286yds
Railway Location (rounded): 9.16m / 14.75Km
OS Location Ref: SP194 555
Territory: London North Western (West Midlands & Chilterns)

Contruction Details

Primary Material: RBE - Early Steel
Structural Form: Beam
Construction Details: Steel trough girders rail on long timbers and plate floor. Brick abutments and wingwalls. Span 8.128m
Listed Structure: No- - -No. of Components: 1

Ownership & Maintainance Details

Structure Owner: Network Rail (CE-Struct)
Cost Recoverable: No- - -Annual Maint. Charge: No

Individual Components

MilesCH.YardsKmAssetNameStatus
9.1613028614.75SpanSTRATFORD/AVON CANAL - Span 1 of 1Functionary
9.1613028714.75SpanSTRATFORD/AVON CANAL - Span 1 of 1Functionary

SCMI Ratings and Inspection Details

Every 6 years, Network Rail carry out detailed inspections on all their structures, which in most cases includes the calculation of an SCMI (or Structures Condition Marking Index). An SCMI score is a number between 0 and 100 and is used to grade the condition of a structure or how close it is to life-expiration. These figures are derived from a 2015 dataset and may not represent the present structure condition.

SCMI Score: 57- - -Bridge Condition Grade: 3- - -Inspection Date: 28/11/2013
57/100
As a (very) rough guide, a score below 40 is considered in poor condition, with a score above 80 in excellent condition.
The chart below shows SCMI scores and their equivalent Bridge Condition Grades (BCG).
SCMI: 80+
BCG: 1
SCMI: 60 - 79
BCG: 2
SCMI: 40 - 59
BCG: 3
SCMI: 20 - 39
BCG: 4
SCMI: -19
BCG: 5